Key Takeaways
  • Oil-based vs Polymer-based: AC Smart Seal uses oil-based formulation that won’t crystallize when exposed to air and moisture, unlike polymer-based sealants that can clog valves and damage test equipment
  • Field-tested reliability: 10+ months of successful operation on a 16-year-old system with no damage to Testo gauges or system components
  • Application limits: Designed specifically for low leak rates and formicary corrosion issues – not suitable for large, obvious leaks
  • External putty option: AC Smart Seal External provides a non-brazing solution for aluminum coils and unique repair situations

Not too long ago, I was under the impression that all internal leak sealant products were equally destructive to air conditioning or refrigeration systems.

About a year and a half ago, there was a heated debate regarding such products on My HVAC Hub powered by HVAC Know It All on Facebook.

I argued that they will, in a matter of time, potentially plug up valves and possibly cause failure of test tools, such as my Testo 557 or Smart Probes.

The Problem with Polymer-Based Sealants

I began to dig a bit deeper into the subject and talked to several technicians.

The conclusion of the discussions was that polymer-based sealants would potentially crystallize within a system, possibly restricting valves and openings if moisture is present.

If this is the case, when a system is opened up and air and moisture are introduced, will the polymer-based sealant crystallize in place?

There are reports of this happening.

It wasn’t long after this I was contacted by Cool Air Products to test out samples of AC Smart Seal Quick Shot and AC Smart Seal External.

AC Smart Seal Quick Shot: An Oil-Based Alternative

Quick Shot is an internal leak sealant developed specifically for air conditioning and refrigeration systems; it is oil-based and comes with the promise of being non-clogging and non-toxic.

It also contains dye and lubricant.

Field Testing on a Problem System

I had a perfect field candidate for Quick Shot.

It was a sixteen-year-old two-ton split cooler unit.

The unit had a history of slow leaks that would take roughly six to seven months to reveal itself.

After a few years of charge adjustments and refrigerant tags, after fixing what was thought to be the leak location, it was time to try something different. When dealing with persistent slow leaks like this, proper refrigerant leak checking procedures are essential for accurate diagnosis before considering any sealant application.

This cooler had 100% redundancy in the form of a backup unit, which made it even more tempting to experiment.

I added Quick Shot using the reusable easy inject.

My fancy Testo gauges were also on the system at the time.

Approximately ten months later, my gauges are still treating me kindly, and the system is leak free and operating well.

Why This Matters for Formicary Corrosion

Why is this good news?

Formicary corrosion, also known as ant nest corrosion, is a serious problem, especially on evaporator coils.

The best solution for this is to replace the coil and or system.

Not that easy. There are budget restraints, scheduling issues, and other obstacles.

Having a viable customer solution is your job as a company and technician.

Just remember, this product is for low leak rates, not large obvious leaks.

AC Smart seal application
AC Smart seal application
AC Smart seal application

Laboratory Testing: No Crystallization

The video below is an experiment that was performed to reveal that AC Smart Seal does not crystallize when in contact with air or moisture.

Long-Term Results

This video was recorded mid summer of 2019.

After the Smart Seal application, the system ran successfully for the remainder of the year and also all of 2020.

AC Smart Seal External: A Unique Repair Solution

It took me almost a year to open up a roll of External.

I witnessed a video on social media of someone using it and wanted to try it myself.

AC Smart Seal External is a sealing putty that can be used in unique situations.

It is truly a genuine truck stock item that, when needed, could be worth its weight in gold, especially on aluminum coils.

Health and Safety Benefits

The other thing that comes to mind while brazing, unless you are wearing a respirator, you are breathing in fumes that do not belong in your body.

Not to mention burning oil and refrigerant, not fun stuff by any means.

We treat AC and refrigeration units like precious gems, but it’s rare to see the tech treat their body in the same manner.

I put it to the test in the video below to see how it stacked up against a brazed joint.

A Year of Testing and Validation

This article was almost an entire year in the making, and I needed to go through the motions to ensure these products worked before I could use them in the field.

Again, my Testo 557 gauges were not affected by using Quick Shot.

As a technician in the HVAC field, we must be diligent in our decision-making and educated about the tools and products we use. Understanding how refrigerant works in the system helps us make informed decisions about when and how to apply leak sealants effectively.

When dealing with persistent leaks, especially in service valve areas, don’t forget to check and properly seal your service valve caps as they’re often an overlooked source of slow leaks.

Finally!

Check out the link to my YouTube channel for more tips, tricks, and troubleshooting videos, and check out The HVAC Know It All podcast here or on your favorite podcast app.

Share this article on:

Gary McCreadie

Gary McCreadie is an HVAC tech, the creator of hvacknowitall.com, the HVAC Know It All Podcast, and owner of McCreadie HVAC & Refrigeration Services

Follow us on:

Save 6% on purchases at TruTech Tools with code knowitall (excluding Fluke and Flir products)

Save 8% at eMotors Direct with code HVACKNOWITALL

Subscribe Now!

Subscribe now and stay up to date with the latest industry trends and HVAC tips and tricks!

Subscribe Now!

Subscribe now and stay up to date with the latest industry trends and HVAC tips and tricks!